This page provides complete metric thread plug gauge size charts for GO and NO-GO members in tolerance class 6H, covering coarse pitch sizes from M1 to M100 per ISO 1502 and ISO 261. All dimensions are in millimetres. The GO gauge pitch diameter limits and NO-GO gauge pitch diameter limits are shown for each size. Use the size and pitch from your engineering drawing to find the correct gauge limits before ordering.

How to Read This Chart

Each row shows one thread size. The GO gauge pitch diameter limits control the minimum material condition of the internal thread — the GO gauge must pass through fully. The NO-GO gauge pitch diameter limits control the maximum material condition — the NO-GO gauge must not engage more than two turns.

// HOW TO READ — COLUMN DEFINITIONS
ColumnDefinitionUnit
ThreadNominal thread designation (e.g. M12×1.75)—
PitchThread pitch — distance between crestsmm
GO PD MaxGO gauge pitch diameter upper limit — gauge must not exceed thismm
GO PD MinGO gauge pitch diameter lower limit — gauge must not be below thismm
NO-GO PD MaxNO-GO gauge pitch diameter upper limitmm
NO-GO PD MinNO-GO gauge pitch diameter lower limitmm
Workpiece 6H MaxMaximum allowable pitch diameter of the inspected internal threadmm
Workpiece 6H MinMinimum allowable pitch diameter of the inspected internal threadmm

Standard reference: All gauge limits on this page are derived from ISO 1502 (gauges for ISO metric threads) and ISO 261 / DIN 13 (ISO general-purpose metric screw threads). Tolerance class 6H applies unless otherwise stated. For other tolerance classes (4H, 5H, 7H), contact GageTools with your specific drawing callout.

M1 – M10 Coarse Pitch — 6H Thread Plug Gauge Limits

Standard: ISO 1502 · ISO 261 · DIN 13. Tolerance class: 6H. All dimensions in mm.

// M1 – M10 COARSE PITCH · 6H · PLUG GAUGE PITCH DIAMETER LIMITS (mm)
Thread Pitch mm GO PD Max GO PD Min NO-GO PD Max NO-GO PD Min Work 6H Max Work 6H Min Order
M10.250.8380.8340.8540.8500.8540.838Quote
M1.20.251.0381.0341.0541.0501.0541.038Quote
M1.40.301.2051.2011.2241.2201.2241.205Quote
M1.60.351.3731.3691.3931.3891.3931.373Quote
M1.80.351.5731.5691.5931.5891.5931.573Quote
M20.401.7401.7361.7631.7591.7631.740Quote
M2.20.451.9081.9031.9331.9281.9331.908Quote
M2.50.452.2082.2032.2332.2282.2332.208Quote
M30.502.6752.6702.7032.6982.7032.675Quote
M3.50.603.1103.1043.1423.1363.1423.110Quote
M40.703.5453.5393.5803.5743.5803.545Quote
M4.50.754.0134.0074.0514.0454.0514.013Quote
M50.804.4804.4744.5204.5144.5204.480Quote
M61.005.3505.3425.4005.3925.4005.350Quote
M71.006.3506.3426.4006.3926.4006.350Quote
M81.257.1887.1797.2487.2397.2487.188Quote
M91.258.1888.1798.2488.2398.2488.188Quote
M101.509.0269.0169.0969.0869.0969.026Quote
Found your size? Get a quote in 24 hours.
M1–M100 · All tolerance classes · ISO/IEC 17025 cert · 72hr delivery · MOQ 1
💬 WhatsApp

M12 – M30 Coarse Pitch — 6H Thread Plug Gauge Limits

// M12 – M30 COARSE PITCH · 6H · PLUG GAUGE PITCH DIAMETER LIMITS (mm)
ThreadPitch mmGO PD MaxGO PD MinNO-GO PD MaxNO-GO PD MinWork 6H MaxWork 6H MinOrder
M111.5010.02610.01610.09610.08610.09610.026Quote
M121.7510.86310.85210.94310.93210.94310.863Quote
M142.0012.70112.68912.79112.77912.79112.701Quote
M162.0014.70114.68914.79114.77914.79114.701Quote
M182.5016.37616.36316.47616.46316.47616.376Quote
M202.5018.37618.36318.47618.46318.47618.376Quote
M222.5020.37620.36320.47620.46320.47620.376Quote
M243.0022.05122.03722.16122.14722.16122.051Quote
M253.0023.05123.03723.16123.14723.16123.051Quote
M273.0025.05125.03725.16125.14725.16125.051Quote
M303.5027.72727.71227.84727.83227.84727.727Quote

M33 – M68 Coarse Pitch — 6H Thread Plug Gauge Limits

// M33 – M68 COARSE PITCH · 6H · PLUG GAUGE PITCH DIAMETER LIMITS (mm)
ThreadPitch mmGO PD MaxGO PD MinNO-GO PD MaxNO-GO PD MinWork 6H MaxWork 6H MinOrder
M333.5030.72730.71230.84730.83230.84730.727Quote
M364.0033.40233.38633.53233.51633.53233.402Quote
M394.0036.40236.38636.53236.51636.53236.402Quote
M424.5039.07739.06039.21739.20039.21739.077Quote
M454.5042.07742.06042.21742.20042.21742.077Quote
M485.0044.75244.73444.90244.88444.90244.752Quote
M525.0048.75248.73448.90248.88448.90248.752Quote
M565.5052.42852.40952.58852.56952.58852.428Quote
M605.5056.42856.40956.58856.56956.58856.428Quote
M646.0060.10360.08360.27360.25360.27360.103Quote
M686.0064.10364.08364.27364.25364.27364.103Quote
Need a large diameter gauge M36–M100? Send your callout.
Large sizes available · Trilock handle for M36+ · ISO/IEC 17025 cert · 72hr–10 day delivery
💬 WhatsApp

M72 – M100 Coarse Pitch — 6H Thread Plug Gauge Limits

// M72 – M100 COARSE PITCH · 6H · PLUG GAUGE PITCH DIAMETER LIMITS (mm)
ThreadPitch mmGO PD MaxGO PD MinNO-GO PD MaxNO-GO PD MinWork 6H MaxWork 6H MinOrder
M726.0068.10368.08368.27368.25368.27368.103Quote
M766.0072.10372.08372.27372.25372.27372.103Quote
M806.0076.10376.08376.27376.25376.27376.103Quote
M856.0081.10381.08381.27381.25381.27381.103Quote
M906.0086.10386.08386.27386.25386.27386.103Quote
M956.0091.10391.08391.27391.25391.27391.103Quote
M1006.0096.10396.08396.27396.25396.27396.103Quote

Fine Pitch Common Sizes — 6H Thread Plug Gauge Limits

Fine pitch threads must always include the pitch in the designation — e.g. M12×1.25, not M12. Fine pitch gauges are not interchangeable with coarse pitch gauges of the same nominal diameter. See our Tolerance Classes Guide for more on fine pitch thread selection.

// FINE PITCH COMMON SIZES · 6H · PLUG GAUGE PITCH DIAMETER LIMITS (mm)
ThreadPitch mmGO PD MaxGO PD MinNO-GO PD MaxNO-GO PD MinWork 6H MaxWork 6H MinOrder
M8×1.01.007.3507.3427.4007.3927.4007.350Quote
M10×1.01.009.3509.3429.4009.3929.4009.350Quote
M10×1.251.259.1889.1799.2489.2399.2489.188Quote
M12×1.01.0011.35011.34211.40011.39211.40011.350Quote
M12×1.251.2511.18811.17911.24811.23911.24811.188Quote
M14×1.51.5013.02613.01613.09613.08613.09613.026Quote
M16×1.51.5015.02615.01615.09615.08615.09615.026Quote
M18×1.51.5017.02617.01617.09617.08617.09617.026Quote
M20×1.51.5019.02619.01619.09619.08619.09619.026Quote
M20×2.02.0018.70118.68918.79118.77918.79118.701Quote
M24×2.02.0022.70122.68922.79122.77922.79122.701Quote
M30×2.02.0028.70128.68928.79128.77928.79128.701Quote

Other Tolerance Classes — 4H, 5H, 7H

The charts above show 6H tolerance limits — the most common for general engineering. For other tolerance classes, the GO and NO-GO pitch diameter limits are different. The table below shows how the limits shift for each class on an M12×1.75 example.

Tolerance ClassGO PD Max (mm)GO PD Min (mm)NO-GO PD Max (mm)NO-GO PD Min (mm)Typical Use
4H10.86310.85410.90710.898Aerospace · Precision assemblies
5H10.86310.85110.92310.911Automotive · Medium precision
6H ★10.86310.85210.94310.932General engineering — standard
7H10.86310.84910.98310.969Plated parts · Easy assembly

Need 4H or 7H gauge limits for a different size? Send your thread callout (e.g. M20×2.5 4H) via WhatsApp or email and we will confirm the exact GO and NO-GO pitch diameter limits for your specific size and tolerance class before production. Response within 24 hours.

Turn a Metric Size into a Gauge RFQ

Send the nominal size and pitch, internal or external thread, tolerance class, plug or ring gauge type, GO/NO-GO requirement, quantity and required inspection or calibration documents.

Request a Metric Thread Gauge Quote →

Browse: Metric thread gauges · Thread plug gauges · Thread ring gauges

Frequently Asked Questions

What is the difference between GO gauge limits and workpiece limits?
The workpiece limits define the acceptable range for the machined thread. The gauge limits are tighter than the workpiece limits — the gauge is manufactured closer to the boundary it controls so that it correctly accepts or rejects workpieces. For a 6H GO gauge, the gauge pitch diameter maximum equals the workpiece pitch diameter minimum — ensuring that a GO gauge just at its own limit still represents the boundary of workpiece acceptance. This is the principle defined in ISO 1502.
Can I use the same gauge for coarse and fine pitch threads of the same diameter?
No. A coarse pitch gauge and a fine pitch gauge of the same nominal diameter have different pitch diameter limits because the pitch changes the thread geometry. An M12×1.75 6H gauge cannot be used to inspect an M12×1.25 6H thread — they require separate gauges. Always check both the nominal diameter and the pitch when ordering or selecting a gauge.
How do I find the correct gauge limits for a size not in this chart?
For sizes not shown in this chart — including non-standard pitches, intermediate diameters, or tolerance classes other than 6H — send your complete thread callout (nominal diameter, pitch, tolerance class) to GageTools via WhatsApp or email. We will calculate the exact gauge limits from ISO 1502 and confirm the correct gauge specification before production. Response within 24 hours.
What does the calibration certificate show for a plug gauge?
The ISO/IEC 17025 calibration certificate for a thread plug gauge shows the actual measured pitch diameter of both GO and NO-GO members, compared against the limits shown in this chart. It also shows the actual major diameter, minor diameter, pitch, and thread angle. Comparing the actual measured value with the limits tells you how much wear budget the gauge has remaining before it needs replacement. See our Calibration Certificate Reading Guide for a full explanation.

Order Any Size from This Chart

GageTools manufactures metric thread plug gauges for all sizes M1 to M100 in coarse and fine pitch, tolerance classes 4H, 5H, 6H, and 7H. ISO/IEC 17025 calibration certificate showing actual measured pitch diameter limits, available on request. MOQ 1 piece. Standard sizes ship in 72 hours.

✓ 20+ years gauge manufacturing

✓ ISO 9001:2015 certified

✓ In-house CNC grinding & inspection

✓ Drawing / RFQ reply within 24h

💬 WhatsApp

Click the email address to copy · Response within 24 hours · ISO/IEC 17025 certificate on request

1 thought on “Metric Thread Plug Gauge Size Chart: M1 to M100 with Tolerance Limits”

  1. Pingback: Thread Plug Gauge: GO/NO-GO Sizes, Standards & Ordering | GageTools

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top
Get a Quote