Tap Tolerance Classes: Matching ISO 1/2/3 and H-Limit Taps to Thread Gauges

GO and NO-GO thread plug gauges used to check tapped holes made with toleranced taps
Tapping · Tap Tolerance Classes · ISO 965 · ASME B1.2
Tap Tolerance Classes:
Matching Taps to Thread Gauges
📅 Updated 2026·10 min read· ISO 1 / ISO 2 / ISO 3 · H-Limits · GO/NO-GO Plugs
// Direct Answer
A tap tolerance class sets where the tap’s pitch diameter sits so that the thread it cuts lands inside a given internal thread class. ISO 1 taps normally suit 4H and 5H, ISO 2 suit 6H (and 4G/5G), and ISO 3 suit 6G, 7H and 8H. Inch taps use H-limits (H1, H2, H3 …) that step the pitch diameter above basic. The tap class is only a starting point: the GO/NO-GO thread plug gauge for the drawing class decides whether the hole is accepted.

Need gauges for this? GageTools manufactures metric GO/NO-GO thread gauges, including thread plug gauges and thread ring gauges in Dongguan, China. Standard sizes ship from stock within 72 hours, MOQ is 1 piece, and every RFQ gets a reply within 24 hours — request a quote.

What a Tap Tolerance Class Actually Controls

A tap is a cutting tool, not a gauge. It is made with its own pitch diameter tolerance, placed so that — under normal cutting conditions — the internal thread it produces falls inside a chosen thread class. The tap class therefore describes the tool, while the thread class on the drawing (for example 6H or 2B) describes the part.

The two are linked but not identical. A tapped hole is almost always slightly larger than the tap that cut it, because of tool run-out, chip pressure, spindle alignment and the way the material behaves. Tap makers build this “cutting oversize” into their classes. That is why a tap’s class and the part’s class have different names, and why the only reliable acceptance check is a thread plug gauge made to the part’s class.

Tap tolerance classes ISO 1, ISO 2, ISO 3 and H-limits compared with internal thread classes 4H to 7H and 6G checked by GO/NO-GO thread plug gauges
Each tap class is positioned inside the internal thread tolerance zone; the GO/NO-GO plug gauge decides acceptance.

If you are new to internal thread classes, our guide to the 6H thread tolerance class explains how the tolerance grade and position letter combine.

ISO Tap Classes: ISO 1, ISO 2 and ISO 3

For ISO metric threads, taps are commonly supplied in three tolerance classes. Each one is aimed at a group of internal thread classes defined under ISO 965. The table shows the usual pairing used by tap makers and buyers.

Tap classTypical internal thread classTypical use
ISO 14H, 5HFine-tolerance threads, precision assemblies
ISO 26H (also 4G, 5G)General engineering — the most common metric tap
ISO 36G, 7H, 8H (also 7G)Looser fit, parts to be plated or coated, easy assembly
Oversize variants (e.g. 6HX, 6GX)6H or 6G in difficult materialsMaterials that close in after tapping, such as some stainless steels and plastics

The pairing is a guideline, not a guarantee. A tap marked ISO 2 can still produce an oversize 6H hole in soft aluminium or an undersize hole in a material that springs back. Always prove the first parts with the GO/NO-GO plug gauge for the drawing class before running production.

6H, 6G and 7G: What Changes for the Gauge

The letter in a metric internal class is the tolerance position. For H, the fundamental deviation is zero: the minimum pitch diameter is the basic size. For G, the whole zone is shifted up by a small fundamental deviation that depends on pitch.

This has a direct consequence for gauges. Because H has zero deviation, the GO thread plug gauge is the same for 4H, 5H, 6H and 7H of the same size and pitch — only the NO-GO plug changes with the tolerance grade. For 6G or 7G, the GO plug is larger, because the minimum material condition has moved up. A 6H GO plug cannot be used to accept a 6G hole.

// 6H HOLE
PositionH (zero deviation)
GO plugBasic minimum PD
NO-GO plug6H maximum PD
Typical tapISO 2
// 6G HOLE
PositionG (positive deviation)
GO plugLarger than 6H GO
NO-GO plug6G maximum PD
Typical tapISO 3

For a side-by-side explanation of the two positions, see 6G vs 6H thread tolerance.

Inch Taps: H-Limits and Unified Classes 2B and 3B

Unified inch taps do not use ISO classes. Instead, ground taps are marked with a pitch diameter limit such as H1, H2, H3 or H4. Each H-limit places the tap’s pitch diameter a set amount above the basic pitch diameter, in small, equal steps for common sizes. H1 is the closest to basic; higher numbers are progressively larger.

Tap makers publish recommended H-limits for each unified class. As a general pattern, lower H-limits suit class 3B holes and slightly higher limits suit class 2B. For 2B holes in general-purpose sizes, H2 or H3 taps are widely used; for 3B holes, H1 or H2. Oversize limits are used for coated parts or materials that close in.

Tap markingPosition relative to basic PDTypical target
H1Closest to basicClass 3B, tight holes
H2One step largerClass 3B or 2B
H3Two steps largerClass 2B, general use
H4 and aboveFurther oversizeAllowance for plating or close-in materials
L-limits (undersize)Below basicSpecial cases only — check with your tap supplier

The acceptance gauge for a unified hole is the GO and NOT GO thread plug gauge made to ASME B1.2 for the drawing class. Our guide to thread class 2B vs 3B gauge selection explains how those gauges differ.

Why the Hole Does Not Match the Tap

Two shops using the same tap class can produce very different holes. The factors below move the tapped pitch diameter up or down, and they explain most “the tap is correct but the gauge fails” disputes.

FactorEffect on holeWhat to do
Material springback (stainless, titanium, some plastics)Hole smaller than tapConsider an oversize tap (e.g. 6HX / higher H-limit)
Soft or gummy material (aluminium, copper)Hole larger than tapConsider a lower tap class; check coolant and chip flow
Spindle / holder misalignmentBell-mouth, oversize at entryUse floating or synchronised holders; check alignment
Tap run-out or regrind errorOversize, uneven flanksInspect taps on receipt; control regrinding
Chip packing in blind holesTorn flanks, tight or loose spotsChange tap geometry, peck or use through-coolant
Tap wearHole gradually undersizeTrack NO-GO and GO results; set a tap-change interval
Need GO/NO-GO thread plug gauges for 6H, 6G or 2B/3B holes?
All sizes & classes · ISO/IEC 17025 cert on request · Stock sizes ship in 72h · MOQ 1

How to Match Taps and Thread Gauges in Practice

The practical rule is simple: choose the tap from the drawing class, and choose the gauge from the drawing class. Never choose the gauge from the tap marking. The drawing class is the contract; the tap is only the means of reaching it.

  1. Read the internal thread callout on the drawing (for example M8x1.25-6H or 1/4-20 UNC-2B).
  2. Order the GO/NO-GO thread plug gauge for exactly that class.
  3. Select a tap class that normally produces that class, using the tap maker’s recommendation for your material.
  4. Tap first-off parts and check them with the GO and NO-GO plugs. The GO must enter the full length by hand; the NO-GO must stop within the permitted turns.
  5. If holes are close to either limit, adjust the tap class, not the gauge.
  6. Record GO/NO-GO results during the run to see tap wear before it produces rejects.

Under ISO 1502 the NO-GO plug may enter no more than two turns; under ASME B1.2 the NOT GO plug may enter no more than three complete turns. The two-turn rule for NO-GO gauges explains how turns are counted.

Taps, Gauges and Coated Parts

Plating, anodising and other coatings reduce the pitch diameter of an internal thread. If the drawing class applies after coating, the hole has to be tapped oversize so that it still accepts the GO plug when finished. This is one of the main reasons ISO 3 taps, G-position taps and higher H-limits exist.

Gauges must match the condition you inspect. If you check parts before coating, the gauge limits may need to account for the coating allowance agreed with your customer. If you check after coating, use the standard gauges for the finished class. Mixing these two conditions is a common cause of rejected batches. Our guide to thread gauges before or after plating covers the options.

Quick Selector: Which Tap Class and Gauge?

My drawing says … which tap class and which gauge?
M10x1.5-6H, steel
→ ISO 2 tap + 6H GO/NO-GO plug
M10x1.5-6G, to be zinc plated
→ ISO 3 tap + 6G GO/NO-GO plug (confirm before/after plating)
M6x1-4H or 5H, precision
→ ISO 1 tap + 4H or 5H plug (same GO, different NO-GO)
1/4-20 UNC-2B
→ H2 or H3 tap + 2B GO/NOT GO plug
10-32 UNF-3B
→ H1 or H2 tap + 3B GO/NOT GO plug
Stainless, holes close in
→ Oversize tap class; gauge stays at drawing class

What to Send When Ordering Thread Plug Gauges

We make GO/NO-GO thread plug gauges for metric, unified and special internal threads, including G-position classes. To quote quickly and correctly, please send:

  • Full thread callout with class (e.g. M12x1.25-6G or 3/8-16 UNC-3B)
  • Whether you need a double-end GO/NO-GO plug or separate members
  • Thread depth and whether the hole is blind (affects gauge length)
  • Condition to be inspected: before or after coating
  • Quantity, and whether an ISO/IEC 17025 calibration certificate is required
  • Drawing or sample photo for special or non-standard threads

Standard metric and unified sizes ship from stock within 72 hours. See our range of thread plug gauges.

Send your thread callout for a same-day quote
All sizes & classes · ISO/IEC 17025 cert on request · Stock sizes ship in 72h · MOQ 1

Need Thread Plug Gauges to Match Your Tapped Holes?

Send the internal thread callout, class and quantity. We confirm the correct GO and NO-GO members and reply with price and lead time within 24 hours.

Send Your Thread Gauge RFQ →

Related: Thread plug gauges · Thread tolerance classes · GO/NO-GO thread gauges

Frequently Asked Questions

Does an ISO 2 tap guarantee a 6H hole?
No. An ISO 2 tap is designed to produce a 6H hole under normal cutting conditions, but material, alignment, tap condition and coolant all change the result. The only proof that a hole is 6H is a GO/NO-GO thread plug gauge made to 6H. Check first-off parts with the gauge and keep checking during the run to detect tap wear.
Is the GO plug gauge the same for 6H and 7H?
Yes. For H-position internal threads the fundamental deviation is zero, so the GO plug is the same for 4H, 5H, 6H and 7H of the same size and pitch. Only the NO-GO plug changes with the tolerance grade. For G-position classes such as 6G the GO plug is larger, so a 6H GO plug cannot accept a 6G hole.
What does H3 mean on an inch tap?
H3 is a pitch diameter limit for a ground inch tap. It places the tap’s pitch diameter a set amount above basic — larger than H1 and H2. H3 taps are widely used for class 2B holes in general-purpose sizes. The acceptance check is still the 2B GO and NOT GO thread plug gauge made to ASME B1.2.
Should I buy a gauge to match my tap class?
No. Buy the gauge to match the thread class on the drawing. The tap class is a production choice you can change at any time; the drawing class is the requirement agreed with your customer. If holes fail the gauge, change the tap class or process, not the gauge. See our thread plug gauge range.
Why are my holes undersize with a new tap?
Some materials, such as stainless steel, titanium and certain plastics, spring back after the tap passes, so the finished hole is smaller than the tap. A new tap may also have a lower pitch diameter than a worn one expected by the process. An oversize tap class usually solves this; the gauge must stay at the drawing class.

✓ 20+ years gauge manufacturing

✓ ISO 9001:2015 certified

✓ In-house CNC grinding & inspection

✓ Drawing / RFQ reply within 24h

Order GO/NO-GO Thread Plug Gauges for Tapped Holes

GageTools makes thread plug gauges for 4H–7H, 6G, 2B, 3B and special internal thread classes, from stock or from your drawing. ISO/IEC 17025 calibration certificate available on request. Standard sizes ship from stock within 72 hours; custom gauges in 10–15 working days. MOQ 1 piece. WhatsApp for fastest response.

💬 WhatsApp Quote 📐 Send Drawing for Quote

Need These Gauges? Get a Quote

Send your thread size or drawing, gauge type and quantity. MOQ is 1 piece; standard catalogue sizes in stock ship within 72 hours. Prefer chat? WhatsApp us.


    PDF, DWG, DXF, STEP, JPG, PNG or ZIP, max 10 MB. A drawing gets you the fastest, most accurate quote.

    + Add more details (optional)

    Scroll to Top
    Get a Quote