// Direct Answer
A helical insert thread is inspected in two stages. Before installation, the STI tapped hole is checked with an STI thread plug gauge. After installation, the thread formed by the insert is checked with a standard GO/NO-GO plug gauge for the nominal screw size, for example an M8 gauge for an M8 insert. The GO member should enter by hand over the required length. Also check insert position, tang removal and coil condition. Screw-locking inserts follow the insert maker’s or drawing’s acceptance rules.

Need gauges for this? GageTools manufactures GO/NO-GO thread plug gauges and thread ring gauges in Dongguan, China. Standard sizes ship from stock within 72 hours, MOQ is 1 piece, and every RFQ gets a reply within 24 hours — request a quote.

Two Threads, Two Checks

A helical (wire thread) insert sits between two threads. On the outside, the insert coils engage a special tapped hole, usually called an STI (screw thread insert) thread, which is larger than the nominal screw thread. On the inside, the insert coils form a nominal internal thread that accepts the standard screw or bolt.

That means two separate inspections with two different gauges. Confusing them is the most common mistake we see.

Inspection flow for helical insert threads before and after installation
Check the STI tapped hole first, then gauge the installed insert with a nominal-size plug gauge.
StageWhat is checkedGauge
Before installationSTI tapped hole in the parent materialSTI thread plug gauge
After installationThread formed by the insert coilsStandard nominal plug gauge (e.g. M8-6H, 1/4-20 UNC-2B)
After installationInsert position, tang, coil conditionVisual, depth checks per drawing

The STI hole check is covered in our guide to STI thread plug gauges. This article focuses on what happens after the insert is in.

Why Check After Installation at All?

If the STI hole passes its gauge and the insert is a certified part, it is tempting to skip the installed check. But installation itself can create faults that neither of the earlier checks would catch:

  • A coil can be bent, crossed or stretched during winding.
  • The insert may be installed too deep, too shallow or at an angle.
  • The drive tang may not be broken off, or may be left in a blind hole where it blocks the screw.
  • Debris, chips or tang fragments can stay in the thread.
  • An oversize STI hole can leave the insert loose, so the installed thread reads large.

An installed check with a nominal plug gauge confirms the thread the customer will actually use. On critical parts it is often a drawing or customer requirement.

Gauging the Installed Insert

The installed insert is gauged with a normal GO/NO-GO thread plug gauge of the nominal size and class, the same type used for a tapped hole without an insert. For an M10x1.5 insert, that is an M10x1.5 plug gauge in the class on the drawing; for a 3/8-16 UNC insert, a 3/8-16 UNC plug gauge in the specified class. Standard sizes are available from our thread plug gauge range.

// GO MEMBER
ShouldEnter by hand
LengthFull required thread
ForceNo wrench
If tightCheck coils, debris
Free-running insertNormal GO rule
// NO-GO MEMBER
ShouldNot exceed limit
Metric (ISO 1502)Max 2 turns
Unified (ASME B1.2)Max 3 complete turns
If it entersCheck STI hole size
Drawing ruleOverrides general rule

Screw-locking inserts are different. They have one or more deliberately deformed locking coils that grip the screw. A standard GO gauge will meet resistance at the locking coil by design. Follow the acceptance method given by the insert manufacturer or on your drawing, which may include gauging only the free-running coils and a separate locking torque test.

Common Faults and What the Gauge Tells You

Gauge resultLikely causeAction
GO will not startTang or debris at entry; insert set too high; first coil bentInspect entry; remove tang/debris; reset position
GO stops partwayCrossed or damaged coil; chips; blind-hole tangInspect with light; replace insert if damaged
GO tight throughoutUndersize STI hole squeezing insert; wrong insertCheck STI hole with its gauge; confirm insert type
NO-GO enters too farOversize STI hole; worn STI tap; loose insertCheck STI tap and STI gauge; replace insert
Results vary along the threadStretched coil, insert installed at an angleReplace insert; review installation tool

Note that many installed-thread faults trace back to the STI tapped hole. When the installed check fails, check the STI hole and its tap before blaming the insert.

Need nominal and STI plug gauges for insert work?
All sizes & classes · ISO/IEC 17025 cert on request · Stock sizes ship in 72h · MOQ 1

Insert Position and Tang Removal

Insert manufacturers specify how far below the part surface the insert should sit, and whether and how the drive tang is removed. These are not thread-gauge checks, but they belong to the same inspection step.

  • Position: an insert set too high can snag the screw head or the mating part; too deep reduces usable thread length. Check against the insert maker’s instruction or your drawing.
  • Tang: on tanged inserts the tang is normally removed after installation. Confirm it is gone and that the fragment has been removed from the hole.
  • Tangless inserts: no tang removal, but check the entry coil is correctly seated.
  • Coil condition: look for bent, crossed or protruding coils with good light.

In blind holes, a tang left at the bottom can stop a GO gauge short and look like a depth problem. Remove the tang before gauging depth. For depth gauging principles, see our blind hole thread gauge guide.

A Practical Inspection Sequence

  1. Gauge the STI tapped hole with the STI GO/NO-GO plug gauge, and check depth.
  2. Clean the hole of chips and fluid.
  3. Install the insert with the correct tool and settings.
  4. Remove the tang (if tanged) and the fragment.
  5. Check position below the surface and coil condition.
  6. Gauge the installed thread with the nominal GO/NO-GO plug gauge, or per the locking-insert method.
  7. Record results, including insert lot and gauge IDs.

On high-volume work, checking the STI hole on a sampling basis and the installed thread on every part is a common split. Your sampling plan should follow your quality system and customer requirements.

Inserts Used for Thread Repair

Helical inserts are also used to repair damaged or stripped threads. The inspection logic is the same, but the STI hole is drilled and tapped in material that may already be damaged or thin. Check wall thickness and the condition of the surrounding material, gauge the STI hole carefully, and gauge the installed insert with the nominal plug gauge before the part returns to service.

Where a repair changes the thread size or type, the drawing or repair instruction should state the new callout, and the gauge follows that callout.

Repair work is often done away from the main production line, in maintenance or rework areas, where gauges are shared and records are thin. Give repair stations their own calibrated STI and nominal plug gauges, and record which gauge was used on each repaired part. That makes it possible to trace and re-check repairs if a gauge is later found out of tolerance.

Which Gauges Do You Need for Insert Work?

Helical insert application — gauges to order
Free-running inserts, metric
→ STI plug gauge + nominal metric GO/NO-GO plug
Free-running inserts, unified
→ STI plug gauge + nominal UN GO/NO-GO plug
Screw-locking inserts
→ STI plug gauge + nominal plug; acceptance per insert maker or drawing
Repair of damaged threads
→ STI plug gauge for the repair size + nominal plug
Special insert or thread
→ Gauges made to your drawing

For metric work, see our metric thread gauges. Special STI or insert threads can be made as custom gauges from drawing.

What to Send When Ordering Gauges for Helical Inserts

  • Nominal thread callout and class after installation (e.g. M8x1.25-6H)
  • STI thread callout for the tapped hole, if you need that gauge too
  • Insert type: free-running or screw-locking; tanged or tangless
  • Blind or through hole, and required thread depth
  • Quantities of STI and nominal gauges
  • Certificate requirement (ISO/IEC 17025 calibration certificate available on request)
Quote STI and nominal plug gauges together
Standard sizes ship in 72h · Custom in 10–15 working days · MOQ 1

Need Gauges for Helical Insert Threads?

Send the nominal thread callout, the STI callout and the insert type. We confirm the gauges and reply with price and lead time within 24 hours.

Send Your Thread Gauge RFQ →

Related: STI thread plug gauges · Thread plug gauges · Blind hole gauging

Frequently Asked Questions

Which gauge checks an installed helical insert?
A standard GO/NO-GO thread plug gauge of the nominal screw size and class, for example an M8x1.25-6H plug for an M8 insert. The STI plug gauge is used before installation to check the tapped hole in the parent material, not the installed insert.
Why does the GO gauge stop on a screw-locking insert?
Screw-locking inserts have deformed locking coils designed to grip the screw, so resistance there is normal. Follow the insert manufacturer’s or drawing’s acceptance method, which may gauge only the free-running coils and add a locking torque test.
The NO-GO gauge enters too far into the installed insert. What is wrong?
Most often the STI tapped hole is oversize, for example from a worn or wrong STI tap, so the insert sits loose. Check the STI hole with its gauge and inspect the tap. Replace the insert once the hole is confirmed correct. See our STI gauge guide.
Do I need to remove the tang before gauging?
Yes, on tanged inserts the tang is normally broken off after installation, and the fragment must be removed. In a blind hole, a tang left at the bottom can stop the GO gauge short and look like a depth or thread fault.
Can you supply both STI and nominal gauges?
Yes. We supply STI thread plug gauges and nominal metric and unified plug gauges, individually or as matched sets. Standard sizes ship from stock within 72 hours, and special sizes are made to drawing in 10–15 working days.
Is the nominal plug gauge for an insert different from a normal plug gauge?
No. The thread formed by an installed free-running insert is a standard nominal internal thread, so a normal GO/NO-GO plug gauge of that size and class is used. What differs is interpretation: a failure may come from the STI hole, the insert or the installation, so investigate all three before rejecting the parent part.

✓ 20+ years gauge manufacturing

✓ ISO 9001:2015 certified

✓ In-house CNC grinding & inspection

✓ Drawing / RFQ reply within 24h

STI and Nominal Plug Gauges for Insert Work

GageTools supplies STI thread plug gauges and nominal GO/NO-GO plug gauges for helical insert installation and thread repair. ISO/IEC 17025 calibration certificate available on request. Standard sizes ship from stock within 72 hours; custom gauges in 10–15 working days. MOQ 1 piece. WhatsApp for fastest response.

💬 WhatsApp Quote 📐 Send Drawing for Quote

Need These Gauges? Get a Quote

Send your thread size or drawing, gauge type and quantity. MOQ is 1 piece; standard catalogue sizes in stock ship within 72 hours. Prefer chat? WhatsApp us.


    PDF, DWG, DXF, STEP, JPG, PNG or ZIP, max 10 MB. A drawing gets you the fastest, most accurate quote.

    + Add more details (optional)

    Scroll to Top
    Get a Quote