Form Tapping and Formed Threads: Hole Size, Split Crest and Gauging

GO and NO-GO thread plug gauges for checking roll-tapped internal threads
Tapping · Form Tapping · Formed Threads · ISO 1502 · ASME B1.2
Form Tapping and Formed Threads:
Hole Size, Split Crest and Gauging
📅 Updated 2026·9 min read· Roll Taps · Minor Diameter · GO/NO-GO Plugs
// Direct Answer
Form tapping, also called roll tapping, makes an internal thread by displacing material instead of cutting it. The pre-drilled hole is larger than a cutting tap drill, and material flows up to form the thread crests, leaving a small split or seam at the minor diameter. Formed threads are accepted with the same GO/NO-GO thread plug gauges as cut threads, because the plugs check pitch diameter and functional size. Minor diameter depends on hole size and must be checked separately.

Need gauges for this? GageTools manufactures GO/NO-GO thread plug gauges and thread ring gauges in Dongguan, China. Standard sizes ship from stock within 72 hours, MOQ is 1 piece, and every RFQ gets a reply within 24 hours — request a quote.

What Form Tapping Is

A form tap has no flutes for cutting. Its cross-section is slightly polygonal, with lobes that press into the wall of the hole. As the tap turns, each lobe pushes material outward and upward along the flanks. The material flows toward the centre of the hole and forms the crests of the internal thread. No chips are produced.

Because the thread is formed rather than cut, the result is similar to an external rolled thread: the surface is burnished, the grain follows the profile and the thread is work-hardened. Form tapping is widely used in aluminium, low- and medium-carbon steels, stainless steels, copper alloys and other ductile materials. It is not suitable for brittle materials such as grey cast iron.

Form tapping process showing pre-drilled hole size, material flow, split crest at minor diameter and GO/NO-GO thread plug gauge inspection
Form taps displace material into the crest; the split crest at the minor diameter is normal.

Form Tapping vs Cut Tapping

AspectCut tappingForm tapping
ChipsYes — must be evacuatedNone
Hole sizeCut tap drill (smaller)Larger form tap hole
Minor diameterSet by drillSet by hole size and material flow
Crest at minor diameterClean, drilled surfaceSplit crest / seam
Thread strengthBaselineOften higher (work-hardened)
TorqueLowerHigher
MaterialsAlmost anyDuctile materials only
Blind holesChip packing riskNo chips to pack
// CHOOSE FORM TAPPING
MaterialDuctile
Chip controlDifficult or critical
VolumeMedium to high
Thread strengthImportant
Blind holesYes
// CHOOSE CUT TAPPING
MaterialBrittle or very hard
Machine torqueLimited
Thin wallsRisk of bulging
Existing drawingSpecifies cut drill size
CoolantLubrication limited

Hole Size for Form Tapping

Hole size is the most important setting in form tapping. The drilled hole must hold enough material to fill the crests, but not so much that the tap is overloaded or the thread overfills. It is always larger than the drill for a cutting tap of the same size.

A common starting point is a hole of about the nominal diameter minus half the pitch. For example, M6x1 is often form tapped from a hole close to 5.5 mm, compared with about 5.0 mm for a cutting tap. Treat this only as a guide: tap makers publish recommended form tap hole sizes, and the best value depends on the material, the tap geometry and the thread depth required.

Hole conditionEffect on formed threadWhat the gauges show
Correct holeCrests well formed, small splitGO enters, NO-GO stops; minor in tolerance
Hole too smallOverfilled crests, high torque, tap breakage riskGO may be tight; minor diameter small
Hole too largeIncomplete crests, low thread heightGO/NO-GO may pass; minor diameter oversize
Hole tapered or bell-mouthedUneven crest fill along depthMinor diameter varies; check at depth

Do not use the cutting tap drill for a form tap. The hole is too small, torque rises sharply and the tap is likely to break. Always use the form tap hole size, and prove it on trial parts.

The Split Crest and Minor Diameter

When material flows up both flanks during form tapping, the two flows meet at the crest of the internal thread — the minor diameter. The result is a small groove or seam running along the crest, often called a split crest or “claw”. It is a normal feature of formed threads, not a defect.

The minor diameter of a formed thread depends on how much material was available to flow, which is set by the hole size. It is not controlled by the tap in the same way as a cut thread. For this reason, the standard minor diameter tolerance for an internal thread can be hard to hold with form tapping. Many drawings and customer specifications allow a larger minor diameter for formed threads, or specify the hole size instead.

MIN
Checking Minor Diameter on Formed Threads
Separate from the thread plug gauge
Options
  • Plain GO/NO-GO plug gauge at minor diameter limits
  • Drilled hole size check before tapping
  • Sectioning of sample parts for crest fill
  • Agreed relaxed minor limits for formed threads
Key point

Agree with your customer how minor diameter is controlled on formed threads before production. If the drawing gives the standard cut-thread minor limits, raise it at the quotation stage rather than after the first rejection.

Gauging Formed Threads with GO/NO-GO Plugs

A formed internal thread is gauged with exactly the same GO/NO-GO thread plug gauges as a cut thread of the same size and class. The GO plug has a full form and checks the functional size — pitch diameter combined with lead and flank errors. The NO-GO plug is truncated and checks pitch diameter alone.

Thread plug gauges are made with clearance at their roots, so they do not touch the crest of the internal thread. That means the split crest does not normally affect the plug result. It also means the plug cannot tell you whether the crest is well filled. This is the same gap as with rolled external threads, and the answer is the same: add a separate minor diameter or hole size check.

  1. Clean the hole. Formed threads have no chips, but lubricant and debris can still mislead the gauge.
  2. Enter the GO plug by hand. It should pass the full thread length without force.
  3. Enter the NO-GO plug by hand. It may start, but must stop within two turns (ISO 1502) or three complete turns (ASME B1.2).
  4. Check minor diameter or hole size according to the agreed method.
  5. Look for burrs or raised material at the hole entry, which can stop the GO plug even when the thread is good.
Need GO/NO-GO plug gauges for roll-tapped holes?
All sizes & classes · ISO/IEC 17025 cert on request · Stock sizes ship in 72h · MOQ 1

Tap Classes for Form Taps

Formed threads spring back slightly after the tap leaves the hole, so the finished pitch diameter is often smaller than the tap. Form taps are therefore commonly made slightly oversize compared with cutting taps for the same thread class. Metric form taps are often marked with an “X” class such as 6HX, and inch form taps with a suitable H-limit.

The gauge always stays at the drawing class. If formed holes fail the GO plug because they are tight, the fix is an oversize form tap or a hole size adjustment, not a different gauge. For more on how tap classes relate to thread classes, read thread tolerance classes 4H to 7H, 6G and 6E.

Common Form Tapping Problems Seen at the Gauge

Gauge resultLikely causeFix
GO plug tight or will not enterHole too small; tap undersize for material; springbackEnlarge hole within limits; use oversize form tap
NO-GO plug enters too farTap oversize or worn in a soft materialUse a smaller tap class; check alignment
GO stops at entry onlyRaised burr or displaced material at the hole mouthCountersink or chamfer the hole before tapping
Plugs pass, minor diameter oversizeHole too large; poor crest fillReduce hole size; check drill wear
Plugs pass, thread strips in useLow thread height from large holeSection parts; tighten hole size control
GO tight near the bottom of a blind holeTap not reaching full depth; lubricationCheck depth setting; improve lubrication

For blind holes, make sure the gauge length and any thread depth requirement match. Our guide to thread gauges for blind holes explains how to specify depth and clearance.

Quick Selector

Formed internal thread — what do I need to check it?
Standard metric formed thread, e.g. M8x1.25-6H
→ Standard 6H GO/NO-GO thread plug + minor diameter check
Unified formed thread, e.g. 1/4-20 UNC-2B
→ 2B GO/NOT GO thread plug to ASME B1.2 + minor check
Deep blind hole
→ Plug with suitable length; state depth in RFQ
Customer asks for crest fill proof
→ Sectioning or agreed minor limits — discuss before production
Plated after forming
→ Gauge for condition inspected; state before/after plating

What to Send When Ordering Gauges for Formed Threads

Formed threads use standard thread plug gauges, so most sizes ship from stock. To quote, please send:

  • Thread callout and class (e.g. M5x0.8-6H, #10-32 UNF-2B)
  • Thread depth and whether holes are blind or through
  • Whether you also need plain plug gauges for minor diameter limits (state the limits)
  • Condition inspected: before or after coating
  • Quantity and certificate requirement (ISO/IEC 17025 on request)

For special sizes or non-standard minor limits, send the drawing and we will confirm the gauge design before quoting. See custom thread gauges from drawing.

Need Thread Plug Gauges for Formed Threads?

Send the thread callout, class, depth and quantity. We confirm the GO and NO-GO plugs and any plain plugs you need, and reply within 24 hours.

Send Your Thread Gauge RFQ →

Related: Thread plug gauges · What is a GO gauge? · Pitch diameter in gauging

Frequently Asked Questions

Can I use normal thread plug gauges on form-tapped holes?
Yes. A formed thread of a given size and class is accepted with the same GO/NO-GO thread plug gauges as a cut thread. The plugs check functional size and pitch diameter, which do not depend on how the thread was made. Add a separate minor diameter or hole size check, because the thread plugs do not touch the crest.
Is the split crest on a formed thread a defect?
No. The split crest is a small seam where material flowing up the two flanks meets at the minor diameter. It is a normal feature of form tapping. A crest that is very low or a minor diameter well above the agreed limit indicates a hole that is too large, which should be corrected.
What hole size should I use for form tapping?
Form tap holes are larger than cutting tap drills. A common starting point is about the nominal diameter minus half the pitch, but tap makers publish recommended sizes for each tap and material. Prove the size on trial parts by checking the GO/NO-GO plug result, minor diameter and crest fill before production.
Why are my form-tapped holes tight on the GO plug?
Formed threads spring back slightly after the tap leaves the hole, and a hole that is too small overfills the thread. Either can make the GO plug tight. Check that you are using the recommended hole size and consider an oversize form tap class such as 6HX. Do not change the gauge; it must stay at the drawing class.
Does form tapping work in cast iron?
Generally no. Form tapping needs ductile material that can flow without cracking. Grey cast iron and other brittle materials are normally cut tapped. Many steels, stainless steels, aluminium and copper alloys form tap well. For any material, the GO/NO-GO thread gauge result is the final acceptance check.

✓ 20+ years gauge manufacturing

✓ ISO 9001:2015 certified

✓ In-house CNC grinding & inspection

✓ Drawing / RFQ reply within 24h

Order Thread Plug Gauges for Formed and Cut Threads

GageTools supplies GO/NO-GO thread plug gauges and plain plug gauges for metric, unified and special internal threads. ISO/IEC 17025 calibration certificate available on request. Standard sizes ship from stock within 72 hours; custom gauges in 10–15 working days. MOQ 1 piece. WhatsApp for fastest response.

💬 WhatsApp Quote 📐 Send Drawing for Quote

Need These Gauges? Get a Quote

Send your thread size or drawing, gauge type and quantity. MOQ is 1 piece; standard catalogue sizes in stock ship within 72 hours. Prefer chat? WhatsApp us.


    PDF, DWG, DXF, STEP, JPG, PNG or ZIP, max 10 MB. A drawing gets you the fastest, most accurate quote.

    + Add more details (optional)

    Scroll to Top
    Get a Quote